Features:
   · Solid zinc alloy casing,
    For its harsh environment
   · Conform to EN60947-5-1,
                  IEC 60947-5-1,
                  UL508,
                  NEMA250,
                  CSA22.2 standard
   · A variety of optional actuators
   · Repeat accuracy (0.03mm linear)
   · Three options cover:
   Compact, standard, explosion-proof
   Model:
   HLS-1A-13H
   HLS-2A-13H
   HLS-3A-13H (Two levels of action)
|
Specifications:
Operating speed: 0.05mm-0.2m/sec
Rated Current/Voltage: 10A/600V AC (EN60947-5-1);
                                  AC15 A600/DC13 Q300
Service life:10 million (minimum)
                Electrical 1 million (minimum)
Operating temperature: -28.9 ~ +85 ℃ (-20 ~ 185 ° F)
Vibration: 25gn (10 .. 150Hz, 11ms) per IEC60068-2-6
Impact: 60gn (9ms) per IEC60068-2-27
Dielectric strength: 2200VAC for 1 minute
Short circuit protection: 10A fuse
Terminal line: 12-22AWG (2.05-0.644 square mm)
Degree of protection: IP67 conforming to IEC60529,
                               NEMA Types 2,4,6,6 P, 12,13
|